Place of Origin:
Henan, China
Brand Name:
ZMS Cable/OEM
Model Number:
YJV33
Insulation Material:
Xlpe
Type:
LOW VOLTAGE
Application:
Construction
Conductor Material:
Copper
Jacket:
PVC
Product Name:
xlpe cable
Rated Voltage:
600/1000V (0.6/1kV)
Dimensions:
1.5,2.5,4,6,10,16,25,35,50,70,95,120,150,185,240,300,400mm2
No. of Cores:
1,2,3,4,5
Conductor:
Stranded round compacted copper or aluminum conductor (Cu/Al)
Armoring Type:
SWA, AWA, STA, DSTA, GSWA
Sheath:
PVC (Polyvinyl Chloride), flame retardant PVC, PE, LSOH, HFFR
Voltage:
1kV~33kV
Operating Temperature:
0°C to 90°C
Standards:
IEC60502-1, BS6346, BS5467, BS6360, BS6724, VDE0276, etc.
Supply Ability
Supply Ability
100 Kilometer/Kilometers per Month xlpe cable
Packaging & Delivery
Packaging Details
Wooden Drum or As Your Request for xlpe cable
Port
qingdao,shanghai,tianjin
Number of Cores & Nominal Cross-section Area
Number of Cores | 1 | 2 | 3 | 3+1 | 4 | 3+2 | 4+1 | 5 |
Section Area (mm2) | 4 - 500 | 2.5 - 500 | 2.5 - 300 | 4 - 300 | 2.5 - 300 | 2.5 -300 | 4 - 300 | 2.5 - 95 |
0.6/3.5 KV cable , It to be used for indoors, in tunnel, in down wells,cable furrow or pipe, underground.
Note: the single core armored cables are used for D.C. system only. As for A.C. system, armor layer should be used of non-magnetic material or magnetic isolation measures.
Cable Structure:
1. Conductor: Copper(Cu) or Aluminum
2. PVC insulation
3. Fill layer
4. Around the package tape
5. Inner Sheath
6. Steel tape armor
7. Outer Sheath
8. Mark
Product Description:
- PVC insulated PVC sheathed power cable (PVC/PVC Cable)
- PVC insulated steel tape armored PVC sheathed power cable (PVC/STA/PVC Cable)
- PVC insulated steel wire armored PVC sheathed power cable (PVC/SWA/PVC Cable)
- Flame retardant PVC insulated PVC sheathed power cable (FR/PVC/PVC Cable)
- Flame retardant PVC insulated steel tape armored PVC sheathed power cable (FR/PVC/STA/PVC Cable)
- Flame retardant PVC insulated steel wire armored PVC sheathed power cable (FR/PVC/SWA/PVC Cable)
Application:
1.steel-tape armored cable is to be laid underground, the cable could bear certain mechanical force.
2.Steel-wire cable is applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint.
Standard: This product adopts the standards of IEC502 & IEC332-3
Scope of application: This item is applied for the alternating current circuitry with voltage (Uo/U) 0.6/1kV for the power supply.
Working conditions:
1) This maximum working temperature of the conductor is 70°C.
2) During having a short(lasting less than 5 seconds)the maximum temperature of the cable conductor for shall not be above 160°C.
3) Environment temperature should be no lower than 0°C for laying the cable;
4) Bending radius allowance of the cable;
single core cable: no steel tape cable 20D: steel tape cable 15D.
3 core cable: no steel tape cable 15D; steel tape cable 12D.
Notes: D practical external diameter of cable
Type, Description & Application of cable
Type | Description | Main application |
VV VLV | PVC insulation PVC sheath power cable | For laying in door, inducts and kin tunnels, but unable to bear pulling force and pressure. |
VV22 VLV22 | PVC insulated steel tape armored PVC sheathed power cable | For laying in doors, in tunnels and direct in ground, able to bear pulling force and pressure. |
VV32 VLV32 | PVC insulated fine steel wire armored PVC sheathed power cable | For laying down wells and under water, able to bear certain axis pulling force. |
VV42 VLV42 | PVC insulated steel wire armored PVC sheathed power cable | For laying down wells and under water, able to bear certain pulling force. |
ZR-VV ZR-VLV | PVC insulated PVC sheathed flame retardant power cable | For laying in door, inducts and in tunnels, but unable to bear pulling force and pressure. |
ZR-VV22 ZR-VLV22 | PVC insulated steel tape armored PVC sheathed flame retardant power cable | For laying in doors, in tunnels and directing ground, able to bear pulling force and pressure. |
ZR-VV32 ZR-VLV32 | PVC insulated fine steel wire armored PVC sheathed flame retardant power cable | For laying in doors, in wells, under water, able to bear certain pulling force. |
ZR-VV42 ZR-VLV42 | PVC insulated steel wire armored PVC sheathed flame retardant power cable | For laying down wells and under water, able to bear certain axis pulling force. |
Core numbers & nominal cross-section area: see Table 2-2
Core No | 1 | 2 | 3 | 3+1 | 4 | 3+2 | 4+1 | 5 |
Area | 4~500 | 2.5~500 | 2.5~300 | 4~300 | 2.5~300 | 2.5~300 | 4~300 | 2.5~95 |
Main properties
No | Test item | Property | ||
1 | Construction | Listed to the tables | ||
2 | Conductor resistance | Listed to the tables | ||
3 | Voltage test | A.C 3.5kV 5min | No breaken | |
4 | Mechanical properties before aging | Tensile strength | Insulation | Min.12.5N/mm² |
Sheath | Min.12.5N/mm² | |||
Elongation at break | Insulation | Min.150% | ||
Sheath | Min.150% | |||
Mechanical properties after aging | Tensile strength | Insulation | 100°C±2°C 7days Min.±12.5N/mm² | |
Sheath | 100°C±2°C 7days Min.±12.5N/mm² | |||
Varying valve of tensile strength | Insulation | 100°C±2°C 7days Min.±25% | ||
Sheath | 100°C±2°C 7days Min.±25% | |||
Elongation at break | Insulation | 100°C±2°C 7days Min.±150% | ||
Sheath | 100°C±2°C 7days Min.±150% | |||
Varying valve of tensile strength | Insulation | 100°C±2°C 7days Min.±25% | ||
Sheath | 100°C±2°C 7days Min.±25% | |||
5 | Flame-retardant property | Comply with GB12666.5-90(CB) and IEC332-3(CB) | ||
6 | Constant of insulation resistivity | Min at 20°C | 36.7 | |
Ki MΩ.km | Min at 70°C | 0.037 |
0.6/1Kv PVC Insulated Steel Tape Armored PVC Sheathed Flame Retardant and Non-flame
Nom.cross sec.area of conductor(mm²) | Single quantity of Conductor | Insu.thickness(mm) | Steel tape thickness(mm) | Outer sheath thickness(mm) | Approx.dia of cable(mm) | Cable approx.weight(kg/km) | D.C. resistance | Test voltage(ac) | ||
Cu | Al | 20°CCu | 20°CAl | Kv/5min | ||||||
2x4 | 1 | 1.0 | 2x0.2 | 1.8 | 14.6 | 210 | 160 | 4.61 | 7.41 | 3.5 |
2x6 | 1 | 1.0 | 2x0.2 | 1.8 | 15.6 | 264 | 192 | 3.08 | 4.61 | 3.5 |
2x10 | 7 | 1.0 | 2x0.2 | 1.8 | 18.2 | 393 | 242 | 1.83 | 3.02 | 3.5 |
2x16 | 7 | 1.0 | 2x0.2 | 1.8 | 20.3 | 541 | 334 | 1.15 | 1.91 | 3.5 |
2x25 | 7 | 1.2 | 2x0.2 | 1.8 | 23.7 | 794 | 469 | 0.727 | 1.20 | 3.5 |
2x35 | 7 | 1.2 | 2x0.2 | 1.8 | 25.9 | 1037 | 585 | 0.524 | 0.868 | 3.5 |
2x50 | 19 | 1.4 | 2x0.2 | 1.8 | 22.6 | 1227 | 610 | 0.387 | 0.641 | 3.5 |
2x70 | 19 | 1.4 | 2x0.2 | 1.9 | 25.0 | 1650 | 747 | 0.268 | 0.443 | 3.5 |
2x95 | 19 | 1.6 | 2x0.5 | 2.1 | 30.2 | 2213 | 988 | 0.193 | 0.320 | 3.5 |
2x120 | 19 | 1.6 | 2x0.5 | 2.2 | 33.6 | 2733 | 1186 | 0.153 | 0.253 | 3.5 |
2x150 | 37 | 1.8 | 2x0.5 | 2.4 | 35.6 | 3396 | 1462 | 0.124 | 0.206 | 3.5 |
2x185 | 37 | 2.0 | 2x0.5 | 2.5 | 38.8 | 4112 | 1726 | 0.0991 | 0.164 | 3.5 |
Place of Origin:
Henan, China
Brand Name:
ZMS Cable/OEM
Model Number:
YJV33
Insulation Material:
Xlpe
Type:
LOW VOLTAGE
Application:
Construction
Conductor Material:
Copper
Jacket:
PVC
Product Name:
xlpe cable
Rated Voltage:
600/1000V (0.6/1kV)
Dimensions:
1.5,2.5,4,6,10,16,25,35,50,70,95,120,150,185,240,300,400mm2
No. of Cores:
1,2,3,4,5
Conductor:
Stranded round compacted copper or aluminum conductor (Cu/Al)
Armoring Type:
SWA, AWA, STA, DSTA, GSWA
Sheath:
PVC (Polyvinyl Chloride), flame retardant PVC, PE, LSOH, HFFR
Voltage:
1kV~33kV
Operating Temperature:
0°C to 90°C
Standards:
IEC60502-1, BS6346, BS5467, BS6360, BS6724, VDE0276, etc.
Supply Ability
Supply Ability
100 Kilometer/Kilometers per Month xlpe cable
Packaging & Delivery
Packaging Details
Wooden Drum or As Your Request for xlpe cable
Port
qingdao,shanghai,tianjin
Number of Cores & Nominal Cross-section Area
Number of Cores | 1 | 2 | 3 | 3+1 | 4 | 3+2 | 4+1 | 5 |
Section Area (mm2) | 4 - 500 | 2.5 - 500 | 2.5 - 300 | 4 - 300 | 2.5 - 300 | 2.5 -300 | 4 - 300 | 2.5 - 95 |
0.6/3.5 KV cable , It to be used for indoors, in tunnel, in down wells,cable furrow or pipe, underground.
Note: the single core armored cables are used for D.C. system only. As for A.C. system, armor layer should be used of non-magnetic material or magnetic isolation measures.
Cable Structure:
1. Conductor: Copper(Cu) or Aluminum
2. PVC insulation
3. Fill layer
4. Around the package tape
5. Inner Sheath
6. Steel tape armor
7. Outer Sheath
8. Mark
Product Description:
- PVC insulated PVC sheathed power cable (PVC/PVC Cable)
- PVC insulated steel tape armored PVC sheathed power cable (PVC/STA/PVC Cable)
- PVC insulated steel wire armored PVC sheathed power cable (PVC/SWA/PVC Cable)
- Flame retardant PVC insulated PVC sheathed power cable (FR/PVC/PVC Cable)
- Flame retardant PVC insulated steel tape armored PVC sheathed power cable (FR/PVC/STA/PVC Cable)
- Flame retardant PVC insulated steel wire armored PVC sheathed power cable (FR/PVC/SWA/PVC Cable)
Application:
1.steel-tape armored cable is to be laid underground, the cable could bear certain mechanical force.
2.Steel-wire cable is applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint.
Standard: This product adopts the standards of IEC502 & IEC332-3
Scope of application: This item is applied for the alternating current circuitry with voltage (Uo/U) 0.6/1kV for the power supply.
Working conditions:
1) This maximum working temperature of the conductor is 70°C.
2) During having a short(lasting less than 5 seconds)the maximum temperature of the cable conductor for shall not be above 160°C.
3) Environment temperature should be no lower than 0°C for laying the cable;
4) Bending radius allowance of the cable;
single core cable: no steel tape cable 20D: steel tape cable 15D.
3 core cable: no steel tape cable 15D; steel tape cable 12D.
Notes: D practical external diameter of cable
Type, Description & Application of cable
Type | Description | Main application |
VV VLV | PVC insulation PVC sheath power cable | For laying in door, inducts and kin tunnels, but unable to bear pulling force and pressure. |
VV22 VLV22 | PVC insulated steel tape armored PVC sheathed power cable | For laying in doors, in tunnels and direct in ground, able to bear pulling force and pressure. |
VV32 VLV32 | PVC insulated fine steel wire armored PVC sheathed power cable | For laying down wells and under water, able to bear certain axis pulling force. |
VV42 VLV42 | PVC insulated steel wire armored PVC sheathed power cable | For laying down wells and under water, able to bear certain pulling force. |
ZR-VV ZR-VLV | PVC insulated PVC sheathed flame retardant power cable | For laying in door, inducts and in tunnels, but unable to bear pulling force and pressure. |
ZR-VV22 ZR-VLV22 | PVC insulated steel tape armored PVC sheathed flame retardant power cable | For laying in doors, in tunnels and directing ground, able to bear pulling force and pressure. |
ZR-VV32 ZR-VLV32 | PVC insulated fine steel wire armored PVC sheathed flame retardant power cable | For laying in doors, in wells, under water, able to bear certain pulling force. |
ZR-VV42 ZR-VLV42 | PVC insulated steel wire armored PVC sheathed flame retardant power cable | For laying down wells and under water, able to bear certain axis pulling force. |
Core numbers & nominal cross-section area: see Table 2-2
Core No | 1 | 2 | 3 | 3+1 | 4 | 3+2 | 4+1 | 5 |
Area | 4~500 | 2.5~500 | 2.5~300 | 4~300 | 2.5~300 | 2.5~300 | 4~300 | 2.5~95 |
Main properties
No | Test item | Property | ||
1 | Construction | Listed to the tables | ||
2 | Conductor resistance | Listed to the tables | ||
3 | Voltage test | A.C 3.5kV 5min | No breaken | |
4 | Mechanical properties before aging | Tensile strength | Insulation | Min.12.5N/mm² |
Sheath | Min.12.5N/mm² | |||
Elongation at break | Insulation | Min.150% | ||
Sheath | Min.150% | |||
Mechanical properties after aging | Tensile strength | Insulation | 100°C±2°C 7days Min.±12.5N/mm² | |
Sheath | 100°C±2°C 7days Min.±12.5N/mm² | |||
Varying valve of tensile strength | Insulation | 100°C±2°C 7days Min.±25% | ||
Sheath | 100°C±2°C 7days Min.±25% | |||
Elongation at break | Insulation | 100°C±2°C 7days Min.±150% | ||
Sheath | 100°C±2°C 7days Min.±150% | |||
Varying valve of tensile strength | Insulation | 100°C±2°C 7days Min.±25% | ||
Sheath | 100°C±2°C 7days Min.±25% | |||
5 | Flame-retardant property | Comply with GB12666.5-90(CB) and IEC332-3(CB) | ||
6 | Constant of insulation resistivity | Min at 20°C | 36.7 | |
Ki MΩ.km | Min at 70°C | 0.037 |
0.6/1Kv PVC Insulated Steel Tape Armored PVC Sheathed Flame Retardant and Non-flame
Nom.cross sec.area of conductor(mm²) | Single quantity of Conductor | Insu.thickness(mm) | Steel tape thickness(mm) | Outer sheath thickness(mm) | Approx.dia of cable(mm) | Cable approx.weight(kg/km) | D.C. resistance | Test voltage(ac) | ||
Cu | Al | 20°CCu | 20°CAl | Kv/5min | ||||||
2x4 | 1 | 1.0 | 2x0.2 | 1.8 | 14.6 | 210 | 160 | 4.61 | 7.41 | 3.5 |
2x6 | 1 | 1.0 | 2x0.2 | 1.8 | 15.6 | 264 | 192 | 3.08 | 4.61 | 3.5 |
2x10 | 7 | 1.0 | 2x0.2 | 1.8 | 18.2 | 393 | 242 | 1.83 | 3.02 | 3.5 |
2x16 | 7 | 1.0 | 2x0.2 | 1.8 | 20.3 | 541 | 334 | 1.15 | 1.91 | 3.5 |
2x25 | 7 | 1.2 | 2x0.2 | 1.8 | 23.7 | 794 | 469 | 0.727 | 1.20 | 3.5 |
2x35 | 7 | 1.2 | 2x0.2 | 1.8 | 25.9 | 1037 | 585 | 0.524 | 0.868 | 3.5 |
2x50 | 19 | 1.4 | 2x0.2 | 1.8 | 22.6 | 1227 | 610 | 0.387 | 0.641 | 3.5 |
2x70 | 19 | 1.4 | 2x0.2 | 1.9 | 25.0 | 1650 | 747 | 0.268 | 0.443 | 3.5 |
2x95 | 19 | 1.6 | 2x0.5 | 2.1 | 30.2 | 2213 | 988 | 0.193 | 0.320 | 3.5 |
2x120 | 19 | 1.6 | 2x0.5 | 2.2 | 33.6 | 2733 | 1186 | 0.153 | 0.253 | 3.5 |
2x150 | 37 | 1.8 | 2x0.5 | 2.4 | 35.6 | 3396 | 1462 | 0.124 | 0.206 | 3.5 |
2x185 | 37 | 2.0 | 2x0.5 | 2.5 | 38.8 | 4112 | 1726 | 0.0991 | 0.164 | 3.5 |